What Are the Steps for Building a Small-Sized Data Center?

What Are the Steps for Building a Small-Sized Data Center?

There are two possibilities here, and your financial condition may influence your choice. First, a new data center is built, but in the second example, an existing building is repurposed to accommodate a new small-sized data center.

A completely new structure allows you to tailor it to your data center’s precise needs, enabling you to achieve better energy metrics and better certification levels. Because the location is in a seismically stable area, it must accommodate future growth. 

Try to choose a location with easy access to electricity and high-speed internet. Moreover, independent optical fiber cables should already be in existence. There is a considerable financial and construction burden if you add a second fiber link to your network. In order to create a fiber connection, the process of procuring land or the rights to use it, and so on, is sometimes lengthy.

What Are the Steps for Building a Small-Sized Data Center?

Steps-for-Building-a-Small-Sized-Data-Center1

Undeniable Value of Power

Every data center relies on a steady supply of electricity that cannot be interrupted. Therefore, it is vital to build small-sized data centers powered by transformers that provide two different energy sources.

An automated transfer switch (APS) with a diesel generator transmits power from a substation to the UPS units. Even though the organization only has one substation, every machine should have two distinct power sources.

Dynamic or rotating UPS systems are now available for data centers that plan to use more than 2 megawatts of electricity. It is like having a transformer, a UPS, and a motor generator all in one! In a nutshell, it is a flywheel in a vacuum box that can store mechanical energy and then convert it into electrical energy when necessary.

Taking A Fire Risk into Account

Even the smallest server rooms should include fire alarms and extinguishers for electrical equipment. In small-sized data centers, it is common practice to use inert gasses, such as the environmentally friendly FM200, to put out small fires. Use demineralized water or sodium instead to save money.

Supervision Is a Necessity

Video cameras, coded doors, and security guards are all essential to secure a building’s physical structure. Remember to keep a close watch on everything. Tracking the energy consumption of each rack is necessary for system analysis and waste prevention.

Heating and cooling systems are equally as important to monitor. Because this is what you are trying to avoid, you should employ procedures and tools to keep an eye on both of them. If you would instead write your own, plenty of commercial options are available.

Everything in this distribution should have its pair, right down to the two wires per rack, and there should be no junctions or shared buses. In order to offer two layers of ground fault protection, the neutral should go at least to the second distribution level.

All incoming feed to the data center networking from the outside should have transient voltage surge suppression equipment installed in line with the main feed. The mechanical panel may also have a TVSS system.

Cooling System Installation and Configuration

The best conventional approach for a reliable facility is a DX system with distinct inputs to the condenser and separate paths to an external location for heat rejection. Using existing chiller capacity may be a possible reason for the upgrade. While chillers provide a cooling supply, we do not consider them necessary for a reference design.

Fault-tolerant chiller designs are available, but they are expensive, time-consuming, and sophisticated. Disruptions will continue to occur as long as chillers remain a viable option for data centers.

Short-term cost-cutting sometimes outweighs long-term design philosophy and intent. With electrically commutated fan-based DX systems, OPEX, maintenance, and the ability to sleep at night are much improved.

There should be a network route and a street path to and from the significant pop. Ideal feed sources are from the air or below ground. There will be fewer issues with construction, traffic, and storms now that there is more diversity. If one road is above ground and the other is below, they may intersect, but this is not ideal.

Quick Facts – All You Need to Know

  • Price of data centers in shipping containers
  • Compare the proposed data centers’ power utilization efficiency (PUE) numbers
  • Contact data center-building businesses 
  • Take a look at this guide on purchasing data centers 
  • Try out Facebook’s open-source ideas
  • Establish at least two additional internet backup fiber connections, each physical route.

Conclusion

If you want to get your small-sized data center up and operating on schedule, you will need the assistance of industry experts. It is necessary to follow steps while building a small-sized data center.